Schneider Motor circuit breaker, TeSys Deca,3P,13-18A,thermal magnetic, crew clamp terminals, toggle handle

Description

Schneider Electric is a multinational corporation specializing in energy management and automation solutions. With operations in over 100 countries, the company offers a wide range of products and services for various industries, including residential, commercial, and industrial.
Schneider Electric is focused on sustainability and innovation, aiming to help their customers manage energy efficiently and reduce their environmental impact.

Schneider Motor Circuit Breaker

Schneider Electric is a well-known brand that manufactures electrical equipment, including motor circuit breakers. Motor circuit breakers are essential components in electrical systems to protect motors from overloads and short circuits. Schneider Electric offers a range of motor circuit breakers designed for different applications and motor sizes.

Motor Circuit Breaker

Motor circuit breakers, also known as motor protection circuit breakers (MPCBs), are specifically designed to protect electric motors from overloads, short circuits, phase unbalances, and other electrical faults. They generally provide different types of protection for motors, such as thermal overload protection and short-circuit protection.

Here are some key points about motor circuit breakers:

  1. Thermal Overload Protection: Motor circuit breakers monitor the current flowing through the motor and trip if an overload condition is detected over a certain period. This helps prevent the motor from overheating and getting damaged.
  2. Short-Circuit Protection: In cases where a short circuit occurs in the motor circuit, the motor circuit breaker will quickly interrupt the power supply to prevent damage to the motor and other equipment.
  3. Phase Unbalance Protection: Some advanced motor circuit breakers can also detect and protect against phase unbalance or loss, which can cause motor inefficiency and damage.
  4. Manual/Automatic Reset: Motor circuit breakers can be manual or automatically resettable, depending on the design and application requirements.
  5. Adjustable Settings: Many motor circuit breakers offer adjustable settings for overload and short-circuit protection, allowing customization based on the motor’s specific requirements.
  6. Remote Monitoring: Some modern motor circuit breakers come with features for remote monitoring, status indication, and communication capabilities, enabling better maintenance and troubleshooting.

Remember, ensuring the correct selection, installation, and maintenance of motor circuit breakers is crucial to maintaining a safe and reliable electrical system.

TeSys Deca – Frame 2

Elevate your electrical system with Schneider Electric’s TeSys Deca Frame 2. Engineered for efficiency and reliability, this frame offers robust construction and seamless integration with TeSys Deca components.

With its versatile design and advanced features, TeSys Deca Frame 2 provides optimal performance for industrial and commercial applications. Trust Schneider Electric for innovative solutions that meet your electrical needs.

GV2RT20

The product code GV2RT20 from Schneider Electric designates a TeSys GV motor circuit breaker engineered for applications with high starting current peaks in motors. Below is an elucidation of its specifications:

  1. Type: TeSys GV motor circuit breaker
  2. Number of poles: 3 poles (3P)
  3. Rated current: 18A
  4. Rated voltage: 690V
  5. Application: Specifically designed for high starting current peak motor applications, capable of handling motors up to 7.5kW@400V.
  6. Protection type: Provides thermal-magnetic protection.
  7. Thermal setting range: 13-18A
  8. Magnetic tripping level: at 20 times the rated current (20xIn)
  9. Breaking capacity: High breaking capacity (Icu) of 15kA@400V, ensuring reliable protection against short circuits.
  10. Connection: Features screw clamp terminals for easy and secure installation.
  11. Start-stop control: Toggle control mechanism, guaranteed for 100,000 cycles in AC-3 applications.
  12. Versatility: Can also be used for the protection of 3-phase transformer applications.
  13. Certifications: Multi-standards certified, including IEC, UL, CSA, CCC, EAC, and Marine standards.
  14. Compliance: Green Premium compliant, meeting RoHS/REACh environmental regulations.

This circuit breaker is specifically engineered to ensure reliable protection and smooth operation in demanding motor and transformer applications, while also adhering to international standards and environmental regulations.

 

 

 

Main
Range TeSys Deca
Product name TeSys GV2 TeSys Deca
product or component type Motor circuit breaker
Device short name GV2RT
Device application Motor protection Transformer
Trip unit technology Thermal-magnetic
Complementary
Poles description 3P
Network type AC
Utilisation category Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 AC-3e conforming to IEC 60947-4-1
Network frequency 50/60 Hz conforming to IEC 60947-4-1
Fixing mode 35 mm symmetrical DIN rail: clipped Panel: screwed (with adaptor plate)
Motor power kW 4 kW at 220/230 V AC 50/60 Hz motor protection high peak current 7.5 kW at 400/415 V AC 50/60 Hz motor protection high peak current 7.5 kW at 440 V AC 50/60 Hz motor protection high peak current 9 kW at 440 V AC 50/60 Hz motor protection high peak current 9 kW at 500 V AC 50/60 Hz motor protection high peak current 15 kW at 690 V AC 50/60 Hz motor protection high peak current 5 kW at 230/240 V AC 50/60 Hz transformer protection 6.3 kW at 230/240 V AC 50/60 Hz transformer protection 10 kW at 400/415 V AC 50/60 Hz transformer protection 10 kW at 440 V AC 50/60 Hz transformer protection 10 kW at 500 V AC 50/60 Hz transformer protection 12.5 kW at 500 V AC 50/60 Hz transformer protection 10 kW at 690 V AC 50/60 Hz transformer protection
Breaking capacity 100 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 6 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
Control type Toggle
[In] rated current 18 A
Thermal protection adjustment range 13…18 A conforming to IEC 60947-4-1
Magnetic tripping current 400 A
[Ith] conventional free air thermal current 18 A conforming to IEC 60947-4-1
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2
Suitability for isolation Yes conforming to IEC 60947-1 § 7-1-6
Power dissipation per pole 2.5 W
Mechanical durability 100000 cycles
Electrical durability 100000 cycles for AC-3 at 415 V In 100000 cycles for AC-3e at 415 V In
Rated duty Continuous conforming to IEC 60947-4-1
Tightening torque 1.7 N.m – on screw clamp terminal
Width 45 mm
Height 89 mm
Depth 78.5 mm
Environment
Standards EN/IEC 60947-2 EN/IEC 60947-4-1
Product certifications CCC UL CSA EAC LROS (Lloyds register of shipping) BV UKCA
IK degree of protection IK04
IP degree of protection IP20 conforming to IEC 60529
Climatic withstand Conforming to IACS E10
ambient air temperature for storage -40…80 °C
Fire resistance 960 °C conforming to IEC 60695-2-11
Ambient air temperature for operation -20…60 °C
Mechanical robustness Shocks: 30 Gn for 11 ms Vibrations: 5 Gn, 5…150 Hz
Operating altitude 2000 m
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 9.300 cm
Package 1 Width 4.800 cm
Package 1 Length 8.500 cm
Package 1 Weight 293.000 g
Unit Type of Package 2 S02
Number of Units in Package 2 24
Package 2 Height 15.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 7.220 kg
Unit Type of Package 3 P06
Number of Units in Package 3 384
Package 3 Height 75.000 cm
Package 3 Width 60.000 cm
Package 3 Length 80.000 cm
Package 3 Weight 128.292 kg

Reviews

There are no reviews yet.

Be the first to review “Schneider Motor circuit breaker, TeSys Deca, 3P, 13-18A, thermal magnetic, crew clamp terminals, toggle handle – GV2RT20”

Your email address will not be published. Required fields are marked *

Schneider Motor circuit breaker,TeSys Deca,3P,13-18A,thermal magnetic,screw clamp terminals,toggle handle - GV2RT20
You're viewing: Schneider Motor circuit breaker, TeSys Deca, 3P, 13-18A, thermal magnetic, crew clamp terminals, toggle handle – GV2RT20 ر.س 310.992
Add to cart
Shopping cart close